CVE Tools

CVE-2023-47279

Delta Electronics InfraSuite Device Master Path Traversal

CVE-2023-47279 is a path traversal in Deltaww Infrasuite Device Master (CVSS 7.5, High).

No known exploitation. EPSS puts it in the 67th percentile. A vendor fix is available.

Check it yourself

OpenVAS · 1 check

e.g. OID 1.3.6.1.4.1.25623.1.0.118566

Run the check

Published Updated Sources: CVE.org, NVD, BDU, CSAF

What to do

The vendor has published a fix. Version details are below where the sources state them.

  • Delta Electronics InfraSuite Device MasterAffected: ≤ 1.0.7Upgrade to: after 1.0.7Stated by: CVE record

Versions as the sources state them. Full version matrix after sign-in

What it is

From the CVE record

In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS67th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

1.1% chance of exploitation activity in the next 30 days, which ranks it in the 67th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

6 events over 938 days, from the signal feeds we watch.

  1. OpenVAS check added
  2. Patch availablerecord updated
  3. Publishedweakness classified, att&ck mapped

Affected products

Technical detail

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Scored 7.5 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity NoneNo integrity impact
  • Availability NoneNo availability impact

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Questions about CVE-2023-47279

Is CVE-2023-47279 being exploited?
No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 1.1%.
Which versions are affected by CVE-2023-47279?
InfraSuite Device Master: ≤ 1.0.7.
How do I fix or mitigate CVE-2023-47279?
The vendor has published a fix. The advisory is on cisa.gov.

Last updated

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for InfraSuite Device Master, not every advisory.