Moxa mgate mb3280
This hub aggregates every CVE we track for Moxa mgate mb3280, a product in the ics ot iot space. Use it to gauge the current risk picture and drill into individual advisories.
13
CVEs tracked
6
Critical
5
High
0
In CISA KEV
Severity distribution
CRITICAL6HIGH5MEDIUM2
Monthly trend
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2024-102026-09
Latest CVEs
The 13 most recently published vulnerabilities affecting Moxa mgate mb3280.
- CVE-2022-27048A vulnerability has been discovered in Moxa MGate which allows an attacker to perform a man-in-the-middle (MITM) attack on the device. This affects MGate MB3170 Series Firmware Version 4.2 or lower...7.4
- CVE-2021-4161ICSA-21-357-01 Moxa MGate Protocol Gateways9.8
- BDU:2020-00962Уязвимость микропрограммного обеспечения преобразователей протоколов Moxa Mgate MB3180, MB3280, MB3480, MB3170, MB3270, связанная с недостатками аутентификации, позволяющая нарушителю войти в систему с пустым именем пользователя и паролем и выполнить произвольные действия на уязвимом устройстве9.8
- CVE-2019-9096An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Insufficient password req...9.8
- CVE-2019-9103An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. An attacker can access se...5.3
- CVE-2019-9104An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configu...7.5
- CVE-2019-9099An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. A Buffer overflow in the ...9.8
- CVE-2019-9098An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. An Integer overflow in th...7.5
- CVE-2019-9097An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. A high rate of transit tr...5.3
- CVE-2019-9102An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. A predictable mechanism o...8.8
- CVE-2019-9101An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is ...7.5
- CVE-2019-9095An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. An attacker may be able t...9.8
- BDU:2019-03267Уязвимость встроенного веб-сервера микропрограммного обеспечения преобразователей протоколов Moxa MGate MB3170, MB3180, MB3270, MB3280, MB3480 и MB3660, позволяющая нарушителю выполнить произвольный код или вызвать отказ в обслуживании9.8