Microscada x sys600
This hub aggregates every CVE we track for Microscada x sys600, a product in the ics ot iot space. Use it to gauge the current risk picture and drill into individual advisories.
20
CVEs tracked
2
Critical
11
High
0
In CISA KEV
Severity distribution
HIGH11MEDIUM7CRITICAL2
Monthly trend
0
0
0
0
0
0
0
0
5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3
2024-102026-09
Latest CVEs
The 15 most recently published vulnerabilities affecting Microscada x sys600.
- CVE-2026-9854A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting the...7.8
- CVE-2026-9853A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated...7.8
- CVE-2026-9852A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user ha...7.8
- CVE-2025-39205A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.6.5
- CVE-2025-39204A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the...6.5
- CVE-2025-39203A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection...6.5
- CVE-2025-39202A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data co...7.3
- CVE-2025-39201A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.6.1
- CVE-2024-7941An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfu...4.3
- CVE-2024-7940The product exposes a service that is intended for local only to all network interfaces without any authentication.8.3
- CVE-2024-3982An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already establi...8.2
- CVE-2024-3980The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the ...9.9
- CVE-2024-4872A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to s...9.9
- CVE-2022-3353IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products5.9
- CVE-2022-3388Input Validation Vulnerability in Hitachi Energy’s MicroSCADA Pro/X SYS600 Products8.8
Product normalization is registry-driven with AI assist and human review. How it works