Homelynk
This hub aggregates every CVE we track for Homelynk, a product in the ics ot iot space. Use it to gauge the current risk picture and drill into individual advisories.
11
CVEs tracked
2
Critical
5
High
0
In CISA KEV
Severity distribution
HIGH5MEDIUM4CRITICAL2
Monthly trend
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2024-072026-06
Latest CVEs
The 11 most recently published vulnerabilities affecting Homelynk.
- CVE-2022-22812A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then execu...6.1
- CVE-2022-22811A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system�s configurations when an attacker pe...8.1
- CVE-2022-22809A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify...5.3
- CVE-2021-22740Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.6.5
- CVE-2021-22739Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.5.9
- CVE-2021-22738Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered ...9.8
- CVE-2021-22736Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service w...7.5
- CVE-2021-22733Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder.7.8
- CVE-2020-7525Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a p...7.5
- CVE-2019-6832A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control...8.3
- CVE-2017-7689A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.9.8