CVE Tools

CVE-2026-89126

Memory Corruption vulnerability in SAP Web Dispatcher

No known exploitation. EPSS puts it in the 38th percentile. No fix published yet.

Check it yourself

OpenVAS · 1 check

e.g. OID 1.3.6.1.4.1.25623.1.0.196626

Run the check

Published Updated Sources: CVE.org, NVD

What to do

No fixed build or workaround is published yet. Limit exposure and watch for a patch.

  • SAP_SE SAP Web DispatcherAffected: HDB 2.00Upgrade to: not statedAffected: KRNL64UC 7.53Upgrade to: not statedAffected: WEBDISP 7.53Upgrade to: not statedAffected: 7.54Upgrade to: not stated + 8 more branchesStated by: CVE record

Versions as the sources state them. Full version matrix after sign-in

Steps

Written by AI from the record
  1. Identify whether your organization runs SAP Web Dispatcher and which version.
  2. Confirm whether the Web Dispatcher instance is reachable from the internet; restrict network access to it if possible while a fix is pending.
  3. Check SAP's official security notes regularly for a patch addressing CVE-2026-89126, as none is available at this time.
  4. Once a fix is released, apply it immediately and verify the update took effect.
  5. In the meantime, place the Web Dispatcher behind strict firewall rules or a trusted network segment to reduce exposure.

What it is

From the CVE record

SAP Web Dispatcher does not sufficiently validate certain network input processed by an internal component. An unauthenticated attacker could send specially crafted network traffic to trigger a memory corruption condition in the affected functionality. Successful exploitation could allow the attacker to execute arbitrary code and fully compromise the system, resulting in a high impact on confidentiality, integrity and availability of the system.

In plain language

Written by AI from the record

A severe flaw in SAP Web Dispatcher could let an attacker take over the system remotely with no login needed, but there's no evidence anyone is exploiting it yet and no fix is available yet, so you should check your exposure now and watch for the patch.

Unauthenticated remote attackers can trigger a heap memory corruption (CWE-122) in SAP Web Dispatcher's internal network-input handling, enabling arbitrary code execution and full system compromise; no vendor patch is currently published.

If you're affected

  • Full system takeover
  • Business operations disruption
  • Exposure of backend SAP data
  • Gateway to internal network access

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS38th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

0.4% chance of exploitation activity in the next 30 days, which ranks it in the 38th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Attention now

Sustained.

Lifecycle

7 events over 4 days, from the signal feeds we watch.

  1. OpenVAS check added
  2. Record updated
  3. Publishedweakness classified, att&ck mapped, record updated, record updated

Affected products

Technical detail

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Scored 10.0 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope ChangedThe exploit can affect other components (e.g. sandbox escape, host compromise from VM)

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for SAP Web Dispatcher, not every advisory.