CVE Tools

CVE-2026-70606

Electron: ProtocolResponse.url reuses the default session cache instead of the registering session

No known exploitation. EPSS puts it in the 16th percentile. Fixed in 40.10.6.

Published Updated Sources: CVE.org, NVD

What to do

Find your product and version, then upgrade to the build on the right.

  • ElectronAffected: >= 40.0.0-alpha.1, < 40.10.6Upgrade to: not statedAffected: >= 41.0.0-alpha.1, < 41.9.1Upgrade to: not statedAffected: >= 42.0.0-alpha.1, < 42.5.1Upgrade to: not statedAffected: >= 43.0.0-alpha.1, < 43.0.0Upgrade to: not statedStated by: CVE record
  • Electronjs ElectronAffected: < 40.10.6Upgrade to: 40.10.6Stated by: NVD

Versions as the sources state them. Full version matrix after sign-in

What it is

From the CVE record

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 40.10.6, 41.9.1, 42.5.1, and 43.0.0, when a custom protocol handler returned a ProtocolResponse with a url and no session, Electron made the upstream request through defaultSession instead of the session that handled the protocol. A cached response could then be reused across otherwise isolated session partitions. Apps that use ProtocolResponse.url, omit ProtocolResponse.session, and rely on separate sessions to isolate content are affected. This issue is fixed in versions 40.10.6, 41.9.1, 42.5.1, and 43.0.0.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS16th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

0.3% chance of exploitation activity in the next 30 days, which ranks it in the 16th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

6 events over 64 days, from the signal feeds we watch.

  1. Patch availablerecord updated
  2. Record updated
  3. Publishedweakness classified, record updated

Affected products

Technical detail

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:N

Scored 5.9 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity HighRequires specific conditions like a race condition or non-default configuration
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction RequiredA user must click a link, open a file, or perform some action

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity LowData modification is possible but limited in scope or consequence
  • Availability NoneNo availability impact

Weaknesses

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Electron, not every advisory.