CVE Tools

CVE-2025-32866

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This...

CVE-2025-32866 is an SQL injection in Siemens Telecontrol Server Basic (CVSS 8.8, High).

No known exploitation. EPSS puts it in the 55th percentile. Fixed in V3.1.2.2.

Check it yourself

No ready-made check. Neither Nuclei nor OpenVAS has one for this CVE yet.

Request a scan

Published Updated Sources: CVE.org, NVD, BDU, CSAF

What to do

Find your product and version, then upgrade to the build on the right.

  • Siemens TeleControl Server BasicAffected: < V3.1.2.2Upgrade to: V3.1.2.2Stated by: CVE record

Versions as the sources state them. Full version matrix after sign-in

What it is

From the CVE record

TeleControl Server Basic before V3.1.2.2 contains multiple SQL Injection vulnerabilities that could allow an attacker to read and write to the application's DB, cause denial of service and execute code in an OS shell with limited "NT AUTHORITY\NetworkService" permissions. Siemens has conducted a root-cause analysis for potential SQL injection vulnerabilities and has identified the locations in the code base where the underlying legacy design pattern has been used in. TeleControl Server Basic V3.1.2.2 has fixed all occurrences in the affected product. Siemens has released a new version for TeleControl Server Basic and recommends to update to the latest version.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS55th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

0.7% chance of exploitation activity in the next 30 days, which ranks it in the 55th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

5 events over 125 days, from the signal feeds we watch.

  1. Patch availablerecord updated
  2. Publishedweakness classified, att&ck mapped

Affected products

And 2 more affected products. See all after sign-in

Technical detail

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Scored 8.8 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required LowRequires basic user-level privileges
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Questions about CVE-2025-32866

Is CVE-2025-32866 being exploited?
No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 0.7%.
Which versions are affected by CVE-2025-32866?
TeleControl Server Basic: < V3.1.2.2.
How do I fix or mitigate CVE-2025-32866?
Upgrade to V3.1.2.2 or later. The advisory is on cisa.gov.

Last updated

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for TeleControl Server Basic, not every advisory.