CVE-2025-27396
CVE-2025-27396 affects Siemens SCALANCE LPE9403 (CVSS 8.8, High).
No known exploitation. EPSS puts it in the 39th percentile. Fixed versions are out.
No public exploit knownFix2 products2 fixed builds listed below
No ready-made check. Neither Nuclei nor OpenVAS has one for this CVE yet.
What to do
Find your product and version, then upgrade to the build on the right.
- Siemens SCALANCE LPE9403Affected: < V4.0Upgrade to: V4.0Stated by: CVE record
- Siemens Scalance Lpe9403 FirmwareAffected: < 4.0Upgrade to: 4.0Stated by: NVD
Versions as the sources state them. Full version matrix after sign-in
What it is
From the CVE record
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the elevation of privileges required to perform certain valid functionality. This could allow an authenticated lowly-privileged remote attacker to escalate their privileges.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.4% chance of exploitation activity in the next 30 days, which ranks it in the 39th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
4 events over 164 days, from the signal feeds we watch.
- Patch availablerecord updated
- Publishedweakness classified
Affected products
And 1 more affected product. See all after sign-in
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Scored 8.8 by NVD.
How it is reached
- Attack Vector NetworkExploitable remotely over the network without any special conditions
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required LowRequires basic user-level privileges
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
Sources
References in the record
- cert-portal.siemens.com/productcert/html/ssa-075201.html
- cert-portal.siemens.com/productcert/html/ssa-075201.html&
- cisa.gov/news-events/ics-advisories/icsa-25-072-06
And 8 more references. See all after sign-in
Questions about CVE-2025-27396
- Is CVE-2025-27396 being exploited?
- No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 0.4%.
- Which versions are affected by CVE-2025-27396?
- SCALANCE LPE9403: < V4.0. Scalance LPE9403 Firmware: < 4.0.
- How do I fix or mitigate CVE-2025-27396?
- Upgrade to a fixed build for your product branch: V4.0, 4.0. The advisory is on cisa.gov.
Last updated
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for SCALANCE LPE9403, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI