CVE-2024-33577
CVE-2024-33577 is a stack overflow in Siemens AG Simcenter Nastran 2306 (CVSS 7.8, High).
No known exploitation. EPSS puts it in the 14th percentile. Fixed versions are out.
No public exploit knownFix3 products2 fixed builds listed below
No ready-made check. Neither Nuclei nor OpenVAS has one for this CVE yet.
What to do
Find your product and version, then upgrade to the build on the right.
- Siemens Simcenter FemapAffected: < V2406Upgrade to: V2406Stated by: CVE record
- Siemens Simcenter NastranAffected: ≥ 2306.0, < 2406.90Upgrade to: 2406.90Stated by: NVD
- Siemens AG Simcenter Nastran 2406Affected: before 2406.90Upgrade to: not statedStated by: BDU
Versions as the sources state them. Full version matrix after sign-in
What it is
From the CVE record
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.2% chance of exploitation activity in the next 30 days, which ranks it in the 14th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
5 events over 507 days, from the signal feeds we watch.
- Patch availablerecord updated
- Publishedweakness classified, att&ck mapped
Affected products
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Scored 7.8 by NVD.
How it is reached
- Attack Vector LocalRequires local access to the vulnerable system (e.g. local login, malicious file)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction RequiredA user must click a link, open a file, or perform some action
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
- Privilege EscalationT1068Exploitation for Privilege Escalationhigh confidence
Sources
References in the record
- cert-portal.siemens.com/productcert/html/ssa-258494.html
- cert-portal.siemens.com/productcert/html/ssa-064222.html
- cert-portal.siemens.com/productcert/csaf/ssa-064222.json
And 10 more references. See all after sign-in
Questions about CVE-2024-33577
- Is CVE-2024-33577 being exploited?
- No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 0.2%.
- Which versions are affected by CVE-2024-33577?
- Simcenter Nastran 2406: before 2406.90. Simcenter Femap: < V2406. Simcenter Nastran: ≥ 2306.0, < 2406.90.
- How do I fix or mitigate CVE-2024-33577?
- Upgrade to a fixed build for your product branch: V2406, 2406.90. The advisory is on cisa.gov.
Last updated
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Simcenter Nastran 2306, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI