CVE Tools

CVE-2021-33553

UDP Technology/Geutebrück camera devices: Command injection in command parameter leading to RCE

Public exploit available. Not confirmed exploited in the wild yet. No fix published yet.

Published Updated Sources: CVE.org, NVD, CSAF

What to do

No fixed build or workaround is published yet. Limit exposure and watch for a patch.

  • Geutebrück E2 SeriesAffected: EBC-21xx 1.12.13.2Upgrade to: not statedAffected: EBC-21xx 1.12.14.5Upgrade to: not statedAffected: EFD-22xx 1.12.13.2Upgrade to: not statedAffected: EFD-22xx 1.12.14.5Upgrade to: not stated + 8 more branchesStated by: CVE record
  • Geutebrück Encoder G-CodeAffected: EEC-2xx 1.12.13.2Upgrade to: not statedAffected: EEC-2xx 1.12.14.5Upgrade to: not statedAffected: EEN-20xx 1.12.13.2Upgrade to: not statedAffected: EEN-20xx 1.12.14.5Upgrade to: not stated + 2 more branchesStated by: CVE record
  • Geutebrueck G-cam Ebc-2110 FirmwareAffected: ≤ 1.12.0.27Upgrade to: after 1.12.0.27Stated by: NVD
  • Geutebrueck G-cam Ebc-2111 FirmwareAffected: ≤ 1.12.0.27Upgrade to: after 1.12.0.27Stated by: NVD
  • Geutebrueck G-cam Efd-2241 FirmwareAffected: ≤ 1.12.0.27Upgrade to: after 1.12.0.27Stated by: NVD

Versions as the sources state them. 13 more products have version data. Full version matrix after sign-in

Steps

Written by AI from the record
  1. Check whether your organization uses any of the listed G-Cam or G-Code camera models (e.g. EBC-2110, EFD-2241, ETHC-2230, EWPC-2270, EEC-2400).
  2. Immediately audit who holds administrator-level accounts on these cameras — this flaw requires that level of access.
  3. Contact Geutebrück / UDP Technology support to ask for a firmware update; no official patched version has been published yet.
  4. Restrict network access to camera management interfaces so only trusted admins can reach them.
  5. Disable or remove unused admin accounts and rotate passwords on remaining ones.

What it is

From the CVE record

Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code.

In plain language

Written by AI from the record

If you use one of these Geutebrück/G-Cam security cameras, an attacker who already has an admin login can hijack the camera completely — it's a real risk but only for accounts with high-level access, so act but don't panic.

CVE-2021-33553 is an OS command injection (CWE-78) in the command parameter of affected UDP Technology/Geutebrück camera firmware, allowing an authenticated high-privilege user to execute arbitrary system commands on the device.

If you're affected

  • Full camera device takeover
  • Surveillance feed tampering or loss
  • Device used as network pivot point
  • Operational disruption to physical security

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS99th
Public exploit
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

1 source with a proof of concept or module.

Exploit links, PoCs and Metasploit modules after sign-in
EPSS

51% chance of exploitation activity in the next 30 days, which ranks it in the 99th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

9 events over 1855 days, from the signal feeds we watch.

  1. EPSS band changemoderate → highepss band change
  2. OpenVAS check added
  3. EPSS band changehigh → moderate
  4. Public exploit / PoCsource: other
  5. Record updated
  6. Publishedweakness classified, att&ck mapped

Affected products

Technical detail

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Scored 7.2 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required HighRequires admin or elevated privileges
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for G-cam Ebc-2110 Firmware, not every advisory. This one: public exploit.