CVE-2021-31890
No known exploitation. EPSS puts it in the 83rd percentile. Fixed versions are out.
What to do
Find your product and version, then upgrade to the build on the right.
- Siemens Capital Embedded AR Classic R20-11Affected: < V2303Upgrade to: V2303Stated by: CVE record
- Siemens PLUSCONTROL 1st GenAffected: All versionsUpgrade to: not statedStated by: CVE record
- Siemens SIMOTICS CONNECT 400Affected: All versions < V0.5.0.0Upgrade to: not statedStated by: CVE record
- Siemens Nucleus Readystart V3Affected: < 2017.02.4Upgrade to: 2017.02.4Stated by: NVD
- Siemens Nucleus Readystart V4Affected: < 4.1.1Upgrade to: 4.1.1Stated by: NVD
Versions as the sources state them. Full version matrix after sign-in
What it is
From the CVE record
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
2.2% chance of exploitation activity in the next 30 days, which ranks it in the 83rd percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
4 events over 1108 days, from the signal feeds we watch.
- Patch availablerecord updated
- Publishedweakness classified
Affected products
And 22 more affected products. See all after sign-in
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Scored 7.5 by NVD.
How it is reached
- Attack Vector NetworkExploitable remotely over the network without any special conditions
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality NoneNo confidentiality impact
- Integrity NoneNo integrity impact
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
Sources
References in the record
- cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
And 33 more references. See all after sign-in
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Siemens, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch