CVE-2021-31340
CVE-2021-31340 is a resource exhaustion in Siemens Simatic RF166C Firmware (CVSS 7.5, High).
No known exploitation. EPSS puts it in the 62nd percentile. A vendor fix is available.
No public exploit knownFixVendor fixNo build named by the sources
No ready-made check. Neither Nuclei nor OpenVAS has one for this CVE yet.
What to do
The vendor has published a fix. Version details are below where the sources state them.
- Siemens SIMATIC RF166CAffected: All versions > V1.1 and < V1.3.2Upgrade to: not statedStated by: CVE record
- Siemens SIMATIC RF185CAffected: All versions > V1.1 and < V1.3.2Upgrade to: not statedStated by: CVE record
- Siemens SIMATIC RF186CAffected: All versions > V1.1 and < V1.3.2Upgrade to: not statedStated by: CVE record
- Siemens SIMATIC RF186CIAffected: All versions > V1.1 and < V1.3.2Upgrade to: not statedStated by: CVE record
- Siemens SIMATIC RF188CAffected: All versions > V1.1 and < V1.3.2Upgrade to: not statedStated by: CVE record
Versions as the sources state them. 45 more products have version data. Full version matrix after sign-in
What it is
From the CVE record
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
1.0% chance of exploitation activity in the next 30 days, which ranks it in the 62nd percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
6 events over 1262 days, from the signal feeds we watch.
- Patch availableworkaround available, record updated
- Publishedweakness classified, att&ck mapped
Affected products
- simatic rf166c firmwareICS / OT / IoT
- simatic rf185c firmwareICS / OT / IoT
- simatic rf186c firmwareICS / OT / IoT
- simatic rf186ci firmwareICS / OT / IoT
- simatic rf188c firmwareICS / OT / IoT
- simatic rf188ci firmwareICS / OT / IoT
- simatic rf360r firmwareICS / OT / IoT
- simatic reader rf610r cmiit firmwareICS / OT / IoT
And 42 more affected products. See all after sign-in
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Scored 7.5 by NVD.
How it is reached
- Attack Vector NetworkExploitable remotely over the network without any special conditions
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality NoneNo confidentiality impact
- Integrity NoneNo integrity impact
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
Sources
References in the record
- cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf
- cert-portal.siemens.com/productcert/csaf/ssa-787292.json
- cert-portal.siemens.com/productcert/txt/ssa-787292.txt
And 12 more references. See all after sign-in
Questions about CVE-2021-31340
- Is CVE-2021-31340 being exploited?
- No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 1.0%.
- Which versions are affected by CVE-2021-31340?
- SIMATIC RF166C: All versions > V1.1 and < V1.3.2. SIMATIC RF185C: All versions > V1.1 and < V1.3.2. SIMATIC RF186C: All versions > V1.1 and < V1.3.2. 47 more products are listed in the record.
- How do I fix or mitigate CVE-2021-31340?
- The vendor has published a fix. The advisory is on cert-portal.siemens.com.
Last updated
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Simatic Rf166c Firmware, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI