CVE Tools

CVE-2021-21830

A heap-based buffer overflow vulnerability exists in the XML Decompression LabelDict::Load functionality of AT&T Labs’ Xmill 0.7. A specially crafted XMI file can lead to remote code execution. A...

CVE-2021-21830 is a heap overflow in Schneider Electric EcoStruxure Control Expert (CVSS 9.8, Critical).

No known exploitation. EPSS puts it in the 84th percentile. A vendor fix is available.

Check it yourself

OpenVAS · 3 checks

e.g. OID 1.3.6.1.4.1.25623.1.0.118373

Run the check

Published Updated Sources: CVE.org, NVD, BDU, CSAF

What to do

The vendor has published a fix. Version details are below where the sources state them.

  • n/a AT&TAffected: AT&T Labs Xmill 0.7Upgrade to: not statedStated by: CVE record
  • Schneider Electric EcoStruxure Control ExpertAffected: before 15.1 HF001Upgrade to: not statedStated by: BDU
  • Schneider Electric SCADAPack RemoteConnectAffected: before R2.7.3Upgrade to: not statedStated by: BDU
  • AT&T Labs XmillAffected: 0.7Upgrade to: not statedStated by: BDU
  • Schneider Electric EcoStruxure Process ExpertAffected: before 2021Upgrade to: not statedStated by: BDU

Versions as the sources state them. Full version matrix after sign-in

What it is

From the CVE record

This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS84th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

2.3% chance of exploitation activity in the next 30 days, which ranks it in the 84th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

6 events over 1777 days, from the signal feeds we watch.

  1. OpenVAS check added
  2. Patch availablerecord updated
  3. Publishedweakness classified, att&ck mapped

Affected products

Technical detail

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Scored 9.8 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Questions about CVE-2021-21830

Is CVE-2021-21830 being exploited?
No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 2.3%.
Which versions are affected by CVE-2021-21830?
EcoStruxure Control Expert: before 15.1 HF001. SCADAPack RemoteConnect: before R2.7.3. EcoStruxure Process Expert: before 2021. 2 more products are listed in the record.
How do I fix or mitigate CVE-2021-21830?
The vendor has published a fix. The advisory is on cisa.gov.

Last updated

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Schneider Electric, not every advisory.