CVE-2021-21815
CVE-2021-21815 is an out-of-bounds write in AT&T (CVSS 7.8, High).
Public exploit available. Not confirmed exploited in the wild yet. A vendor fix is available.
Public exploit: 1 sourceFixVendor fixNo build named by the sources
e.g. OID 1.3.6.1.4.1.25623.1.0.118373
What to do
The vendor has published a fix. Version details are below where the sources state them.
- n/a AT&TAffected: AT&T Labs Xmill 0.7Upgrade to: not statedStated by: CVE record
- Schneider Electric EcoStruxure Control ExpertAffected: before 15.1 HF001Upgrade to: not statedStated by: BDU
- Schneider Electric SCADAPack RemoteConnectAffected: before R2.7.3Upgrade to: not statedStated by: BDU
- AT&T Labs XmillAffected: 0.7Upgrade to: not statedStated by: BDU
- Schneider Electric EcoStruxure Process ExpertAffected: before 2021Upgrade to: not statedStated by: BDU
Versions as the sources state them. Full version matrix after sign-in
What it is
From the CVE record
A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT&T Labs' Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger this vulnerability.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
1 source with a proof of concept or module.
Exploit links, PoCs and Metasploit modules after sign-in- EPSS
0.3% chance of exploitation activity in the next 30 days, which ranks it in the 27th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
The patch came 471 days before any public exploit.
- OpenVAS check added
- Public exploit / PoCsource: other
- Patch availablerecord updated
- Publishedweakness classified, att&ck mapped
Affected products
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Scored 7.8 by NVD.
How it is reached
- Attack Vector LocalRequires local access to the vulnerable system (e.g. local login, malicious file)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required LowRequires basic user-level privileges
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
- Initial AccessT1190Exploit Public-Facing Applicationhigh confidence
- Privilege EscalationT1068Exploitation for Privilege Escalationhigh confidence
Sources
References in the record
- talosintelligence.com/vulnerability_reports/TALOS-2021-1280
- se.com/ww/en/download/document/SEVD-2021-222-02/&
- talosintelligence.com/vulnerability_reports/TALOS-2021-1280&
And 22 more references. See all after sign-in
Questions about CVE-2021-21815
- Is CVE-2021-21815 being exploited?
- Not confirmed. Public exploit code exists (1 source), but CVE-2021-21815 is not in CISA KEV. EPSS puts the chance of exploitation in the next 30 days at 0.3%.
- Which versions are affected by CVE-2021-21815?
- EcoStruxure Control Expert: before 15.1 HF001. SCADAPack RemoteConnect: before R2.7.3. EcoStruxure Process Expert: before 2021. 2 more products are listed in the record.
- How do I fix or mitigate CVE-2021-21815?
- The vendor has published a fix. The advisory is on cisa.gov.
Last updated
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Schneider Electric, not every advisory. This one: public exploit.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI