CVE Tools

CVE-2021-21810

CVE-2021-21810 is a heap overflow in AT&T Labs (CVSS 9.8, Critical).

No known exploitation. EPSS puts it in the 67th percentile. A vendor fix is available.

Check it yourself

OpenVAS · 3 checks

e.g. OID 1.3.6.1.4.1.25623.1.0.118373

Run the check

Published Updated Sources: CVE.org, NVD, BDU, CSAF

What to do

The vendor has published a fix. Version details are below where the sources state them.

  • n/a AT&T LabsAffected: AT&T Labs Xmill 0.7Upgrade to: not statedStated by: CVE record
  • Schneider Electric EcoStruxur Process ExpertAffected: before V2021Upgrade to: not statedStated by: BDU
  • Schneider Electric EcoStruxure Control ExpertAffected: before 15.1 HF001Upgrade to: not statedStated by: BDU
  • Schneider Electric SCADAPack RemoteConnectAffected: before R2.7.3Upgrade to: not statedStated by: BDU
  • AT&T Labs XmillAffected: 0.7Upgrade to: not statedStated by: BDU

Versions as the sources state them. Full version matrix after sign-in

What it is

From the CVE record

A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT&T Labs’ Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS67th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

1.1% chance of exploitation activity in the next 30 days, which ranks it in the 67th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

6 events over 1773 days, from the signal feeds we watch.

  1. OpenVAS check added
  2. Patch availablerecord updated
  3. Publishedweakness classified, att&ck mapped

Affected products

Technical detail

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Scored 9.8 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Questions about CVE-2021-21810

Is CVE-2021-21810 being exploited?
No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 1.1%.
Which versions are affected by CVE-2021-21810?
EcoStruxur Process Expert: before V2021. EcoStruxure Control Expert: before 15.1 HF001. SCADAPack RemoteConnect: before R2.7.3. 2 more products are listed in the record.
How do I fix or mitigate CVE-2021-21810?
The vendor has published a fix. The advisory is on cybersecurity-help.cz.

Last updated

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Schneider Electric, not every advisory.