CVE-2018-19029
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, d...
CVE-2018-19029 is a null-pointer deref in LCDS Laquis SCADA (CVSS 7.8, High).
No known exploitation. EPSS puts it in the 86th percentile. No fix published yet.
No public exploit knownFixNone yetNo fix or workaround published
e.g. OID 1.3.6.1.4.1.25623.1.0.107455
What to do
No fixed build or workaround is published yet. Limit exposure and watch for a patch.
- LCDS Laquis SCADAAffected: All versions prior to version 4.1.0.4150Upgrade to: not statedStated by: CVE record
Versions as the sources state them. Full version matrix after sign-in
What it is
From the CVE record
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
2.7% chance of exploitation activity in the next 30 days, which ranks it in the 86th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
5 events over 2697 days, from the signal feeds we watch.
- OpenVAS check added
- Record updated
- Publishedweakness classified, att&ck mapped
Affected products
Technical detail
CVSS 3.0 vector
Open in the CVSS calculatorCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Scored 7.8 by NVD.
How it is reached
- Attack Vector LocalRequires local access to the vulnerable system (e.g. local login, malicious file)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction RequiredA user must click a link, open a file, or perform some action
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
Sources
Questions about CVE-2018-19029
- Is CVE-2018-19029 being exploited?
- No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 2.7%.
- Which versions are affected by CVE-2018-19029?
- LCDS Laquis SCADA: All versions prior to version 4.1.0.4150.
Last updated
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for LCDS Laquis SCADA, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI