CVE Tools

CVE-2018-12031

Exploitation likely. EPSS gives it a 19% chance of exploitation in the next 30 days. No fix published yet.

Published Updated Sources: CVE.org, NVD

What to do

No fixed build or workaround is published yet. Limit exposure and watch for a patch.

Steps

Written by AI from the record
  1. Check whether you run Eaton Intelligent Power Manager and confirm whether the installed version is v1.6.
  2. Limit access to the Intelligent Power Manager web interface to trusted administrator networks; remove public internet access.
  3. Contact Eaton or your support provider for the exact fixed version or official mitigation, as no patch information is currently available.
  4. Review web-server and application logs for unusual requests to the firmware-download function or file-path manipulation attempts.

What it is

From the CVE record

Local file inclusion in Eaton Intelligent Power Manager v1.6 allows an attacker to include a file via server/node_upgrade_srv.js directory traversal with the firmware parameter in a downloadFirmware action.

In plain language

Written by AI from the record

Eaton Intelligent Power Manager v1.6 has a critical flaw that can let an internet attacker take control of the system, so affected businesses should act now.

Unauthenticated directory traversal/local file inclusion in Eaton Intelligent Power Manager v1.6 through the firmware parameter of the downloadFirmware action in server/node_upgrade_srv.js.

If you're affected

  • Power-management system takeover
  • Configuration data exposure
  • Service disruption
  • Potential ransomware entry point

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS97th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

19% chance of exploitation activity in the next 30 days, which ranks it in the 97th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

23 events over 3030 days, from the signal feeds we watch.

  1. EPSS band changelow → moderateepss band change
  2. EPSS band changemoderate → lowepss band change
  3. EPSS band change0 → moderateepss band change
  4. EPSS band changemoderate → 0epss band change
  5. EPSS band change0 → moderateepss band change
  6. EPSS band changemoderate → low

Affected products

Technical detail

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Scored 9.8 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Eaton, not every advisory.