F1203 firmware
This hub aggregates every CVE we track for F1203 firmware, a product in the networking infrastructure space. Use it to gauge the current risk picture and drill into individual advisories.
34
CVEs tracked
7
Critical
26
High
0
In CISA KEV
Severity distribution
HIGH26CRITICAL7MEDIUM1
Monthly trend
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2024-092026-08
Latest CVEs
The 15 most recently published vulnerabilities affecting F1203 firmware.
- CVE-2024-32310Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.8.0
- CVE-2024-32312Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.5.7
- CVE-2024-2979Tenda F1203 openSchedWifi setSchedWifi stack-based overflow8.8
- CVE-2024-2978Tenda F1203 setcfm formSetCfm stack-based overflow8.8
- CVE-2024-2977Tenda F1203 QuickIndex formQuickIndex stack-based overflow8.8
- CVE-2024-2976Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow8.8
- CVE-2023-38936Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were di...9.8
- CVE-2023-38933Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a sta...9.8
- CVE-2023-38934Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.9.8
- CVE-2023-38940Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.9.8
- CVE-2023-38931Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1...9.8
- CVE-2023-38930Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in th...9.8
- CVE-2022-46541Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the ssid parameter at /goform/fast_setting_wifi_set.7.5
- CVE-2022-46542Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/addressNat.7.5
- CVE-2022-46543Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mitInterface parameter at /goform/addressNat.7.5
Product normalization is registry-driven with AI assist and human review. How it works