SMA1000
19 CVEs tracked. 6 of them are in CISA KEV.
This hub aggregates every CVE we track for SMA1000, a product in the networking infrastructure space. Use it to gauge the current risk picture and drill into individual advisories.
SMA1000 CVEs per month
| Month | CVEs |
|---|---|
| 2024-12 | 0 |
| 2025-01 | 1 |
| 2025-02 | 0 |
| 2025-03 | 0 |
| 2025-04 | 1 |
| 2025-05 | 1 |
| 2025-06 | 0 |
| 2025-07 | 0 |
| 2025-08 | 0 |
| 2025-09 | 0 |
| 2025-10 | 0 |
| 2025-11 | 0 |
| 2025-12 | 1 |
| 2026-01 | 0 |
| 2026-02 | 0 |
| 2026-03 | 0 |
| 2026-04 | 4 |
| 2026-05 | 0 |
| 2026-06 | 0 |
| 2026-07 | 2 |
| 2026-08 | 0 |
| 2026-09 | 2 |
| 2026-10 | 4 |
| 2026-11 | 0 |
Severity
How the 19 CVEs score on CVSS. Severity is not exploitation: KEV is counted above.
- Critical4
- High11
- Medium4
Latest CVEs
The 15 most recently published vulnerabilities affecting SMA1000.
- CVE-2026-102258Post-authentication Stored Cross-Site Scripting (XSS) vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a rem...6.1
- CVE-2026-102257A Zip Slip vulnerability in the in the SMA1000 Appliance Management Console (AMC) interface allows an attacker to extract files outside the intended destination directory using a specially crafted ...7.2
- CVE-2026-102256Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability has been identified in the SMA1000 appliance which in specific condition...7.8
- CVE-2026-102255A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. By abusing this path, a remote unauthenticated attacker coul...10.0
- CVE-2026-83549Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) wh...7.8
- CVE-2026-83548A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. A remote unauthenticated attacker could potentially exploit ...10.0
- CVE-2026-15410Post-authentication improper control of generation of code ('Code Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could ...7.2
- CVE-2026-15409A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. A remote unauthenticated attacker could potentially cause the appliance to make...10.0
- CVE-2026-4116Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN user to bypass Workplace/Connect Tunnel TOTP authentication.7.2
- CVE-2026-4114Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN admin to bypass AMC TOTP authentication.6.6
- CVE-2026-4113An observable response discrepancy vulnerability in the SonicWall SMA1000 series appliances allows a remote attacker to enumerate SSL VPN user credentials.7.2
- CVE-2026-4112Improper neutralization of special elements used in an SQL command (“SQL Injection”) in SonicWall SMA1000 series appliances allows a remote authenticated attacker with read-only administrator p...7.2
- CVE-2025-40602A local privilege escalation vulnerability due to insufficient authorization in the SonicWall SMA1000 appliance management console (AMC).6.6
- CVE-2025-40595A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. By using an encoded URL, a remote unauthenticated attacker could potentially ca...7.2
- CVE-2025-2170A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface, which in specific conditions could potentially enable a remote unauthenticated ...7.2