CVE-2026-21639
CVE-2026-21639 is a buffer overflow in Ui Airmax Ac Firmware (CVSS 8.8, High).
No known exploitation. EPSS puts it in the 34th percentile. Fixed versions are out.
No public exploit knownFix5 products4 fixed builds listed below
No ready-made check. Neither Nuclei nor OpenVAS has one for this CVE yet.
What to do
Find your product and version, then upgrade to the build on the right.
- Ubiquiti Inc airMAX ACAffected: < 8.7.21Upgrade to: 8.7.21Stated by: CVE record
- Ubiquiti Inc airMAX MAffected: < 6.3.24Upgrade to: 6.3.24Stated by: CVE record
- Ubiquiti Inc airFiber AF60-XGAffected: < 1.2.3Upgrade to: 1.2.3Stated by: CVE record
- Ubiquiti Inc airFiber AF60Affected: < 2.6.8Upgrade to: 2.6.8Stated by: CVE record
- Ui Airmax Ac FirmwareAffected: < 8.7.21Upgrade to: 8.7.21Stated by: NVD
Versions as the sources state them. 3 more products have version data. Full version matrix after sign-in
What it is
From the CVE record
A malicious actor in Wi-Fi range of the affected product could leverage a vulnerability in the airMAX Wireless Protocol to achieve a remote code execution (RCE) within the affected product.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.4% chance of exploitation activity in the next 30 days, which ranks it in the 34th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
7 events over 203 days, from the signal feeds we watch.
- Patch availablerecord updated
- Patch availablerecord updated
- Publishedweakness classified, att&ck mapped
Affected products
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Scored 8.8 by NVD.
How it is reached
- Attack Vector AdjacentRequires access to the local network (e.g. same Wi-Fi, Bluetooth)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
- ExecutionT1059Command and Scripting Interpreterhigh confidence
- Initial AccessT1190Exploit Public-Facing Applicationhigh confidence
- Privilege EscalationT1068Exploitation for Privilege Escalationhigh confidence
Sources
Questions about CVE-2026-21639
- Is CVE-2026-21639 being exploited?
- No exploitation is confirmed and no public exploit is known. EPSS puts the chance of exploitation in the next 30 days at 0.4%.
- Which versions are affected by CVE-2026-21639?
- Airmax Ac Firmware: < 8.7.21. airMAX AC: < 8.7.21. airMAX M: < 6.3.24. 5 more products are listed in the record.
- How do I fix or mitigate CVE-2026-21639?
- Upgrade to a fixed build for your product branch: 8.7.21, 6.3.24, 1.2.3, 2.6.8. The advisory is on community.ui.com.
Last updated
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Airmax Ac Firmware, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI